SECTION 414-01: Battery, Mounting and Cables
| 2014 Mustang Workshop Manual
|
DIAGNOSIS AND TESTING
| Procedure revision date: 01/07/2013
|
GR1 190 V3.0 Intelligent Diagnostic Charger
162-00036 |
Battery condition is determined by measuring battery terminal voltage after a specific discharge current is applied for a specified time period.
Test Step | Result / Action to Take |
---|---|
A1 TEST THE BATTERY CONDITION | |
NOTE: A red test-eye indicates the battery is discharged, not necessarily damaged. NOTE: Failure to fully charge the battery before retesting may cause false readings. | Yes
RETURN the battery to service. No If the analyzer reads REPLACE BATTERY or REPLACE-BAD CELL, INSTALL a new battery. REFER to Battery and Battery Tray — Exploded View in this section. |